GAMMA SYSTEM
10044 Pianezza / TO
Via Torino, 24/I
Tel. +39 0119682466 r.a.
Fax +39 0119674211

e-mail:info@gammasystem.com
www.gammasystem.com

Cap. Sociale €10.400 i,v,
REA 553355 - R.I.n. 4121/81 Part. Iva 02363550019
TECHNICAL DOCUMENTATION

download



Control Units

   

The control unit is used to continually control the functionality of pressure sensitive MATS, pressure sensitive EDGES and pressure sensitive BUMPERS.

Two safety relays with forced open contacts detect voltage at the leads of sensor terminals (safety mats, edges and bumpers).The control unit is fundamental to continually check the good operation of safety devices. This means being sure that when such devices are activated, the desired electrical signal is generated.

The control unit is capable of controlling several safety devices.

 

Control units for 8.2kΩ conductive edge


Two symmetric circuits detect the current in the edge, adjusted for a resistance of 8,2 kΩ. When the circuits detect a variation of ± 4 kΩ, caused by a fault or operation of the edge, they desexcite the outlet relays, that open the safety contacts.


   
TECHNICAL FEATURES GP02/E GP02/E-S2 GP03 GP03T
GP03T.1
GP02R
(8,2 kΩ)
GP02R-C
(8,2 kΩ)
Safety category 3 (three) according to
EN 954 (ICEPI)
4 (four) according to EN954 (TÜV) 3 (three) according to EN 954 (ICEPI)
Supply voltage 24 Vdc ± 10% 24 Vac/dc
110 Vac
24Vdc ±10% 24 Vac/dc
Current absorbed with reset
module 24Vdc
90 mA 100 mA 125 mA 110 mA
Safety output (1) 1N.O 2N.O 1N.O 3N.O 2N.O
Dimension of container 35x90xh70 mm 72x90xh70 mm 75x90xh105 22.5x99x
h114.5mm
22.5x99xh114 mm 120 x155x h75 mm
Sensors to be used and safety category MATS, EDGES
SHOCK- ABSORBERS cat. 2
MATS, EDGES
SHOCK- ABSORBERS cat. 3
8.2kΩ conductive edge cat. 3
Approvals ICEPI ICEPI | TÜV NORD ICEPI
(1) Contact closed with sensor supplied, not operated